12V High Frequency AGM IntelliCharger, 15A
Physical Specifications
Dimensions (W x H x D) : 8.3” x 4.7” x 2.3” (211mm x 119mm x 60mm)
Weight: 2.8 lbs (1.27 kg)
AC Input Connections : 5.0’ (1.5 m) AWG 16
DC Output Connections : 3.9’ (1.19m) AWG 10
AC Input Specifications
AC Input Voltage : 100-120 VAC, 47-63 Hz
AC Input Current : 7A RMS fuse protected
Three Stage Charging
At the heart of the technology in all HF Chargers is the three distinct charging stages. During the first stage, called “Bulk”
charging, the current is fixed and the voltage is allowed to float. During this stage, 80% of the battery’s capacity is restored.
When the battery’s cell voltage is up to the correct level, the second stage called “Absorption” charging is engaged. During
this stage the voltage is fixed and the current is allowed to float. The battery is brought to 100% during this stage and the
cells are equalized. The third stage is “Float” charging. During this stage the voltage and current are reduced to a level that
will maintain the battery indefinitely.
Several microprocessors are used to tightly control the entire process. This is the same technique that battery manufacturers
recommend and use in the production of new batteries and it is the fastest and safest technique for battery charging.
Compatible With Most Lead-acid Batteries Including AGM
Lead-acid batteries have different charging requirements based on their specific design. Overcharging will reduce the life
of any battery as sealed valve regulated batteries are especially sensitive to high charging voltages and overcharging.
Overcharging an AGM or gel-cell battery will cause permanent damage.
Voltage Monitoring
The battery’s terminal voltage is measured every five minutes by the on-board microprocessors and this information is
analyzed in addition to the elapsed time to dynamically control the battery charger for optimum charging performance.
Automatic Computer Analysis/Auto Shutdown
The microprocessors will analyze the battery when connected. If the battery’s voltage is below 4V the charger may not
recognize the battery is connected and will not begin charging. Likewise, if the battery will not come up to the correct voltage
in a ten-hour period the microprocessor control board will automatically shut the charger off.
UL Approved Battery Cables
3.9 feet of durable battery cables are provided that are resistant to cuts and abrasion. The copper plated battery clamps are
compact and custom designed easy connections. All clamp connections are soldered for maximum current flow.
Internal Cooling Fan
A cooling fan automatically operates during charging to keep the circuit and other internal components at a constant safe
temperature.